Specialty Fuses
Semiconductor fusesMedium voltage fusesHigh voltage fusesLow voltage fuses
Miniature cylindrical fuses
Hill Technical Sales specializes in providing innovative
fuse protection for:
Our semiconductor fuses offer protection against
short circuit faults with low I2T values, low power loss
and high interrupt ratings. Fuses have high current rating and UL
recognition.
Our fuses for medium voltage capacitors / capacitor
banks have high interrupt rating of 63kA and can be easily direct
mounted to capacitor bushing with: threaded holes on both ends, a
threaded hole and L-bracket or L-brackets on both sides. Specials
mounting for your unique requirements are available.
We also have fuses for medium and high voltage applications
like; switch gear / motor protection / transformers including submersibles
and cable feeders.
Other unique fuses include, miniature electronic
fuses (DC rated fuses for 6000 VDC and above), bottle fuses for all
sizes DIAZED, NEOZED, Cylindrical type, Wind-Power inverters, Traction,
Inverters, Choppers, Mining, Turbine, Switchgear, ASD, AC/DC Drives,
UPS, Forklift, Navy. Communication, and many other applications
Other fuse holders and accessories are available
to support your needs.
|
Semiconductor Fuses |
Class |
Voltage Rating |
Current Rating |
Standards |
Product
Reference |
AR |
660 to 1000VAC |
10 to 400A |
DIN 43653; IEC 60269-4; DIN VDE 0636-40; UL 248-13 |
|
gR/aR |
440 to 500VAC |
2 to 200A |
DIN VDE 0636-40; DIN 49515/49360 |
|
gR/aR |
660 to 5000VDC |
6 to 800A |
IEC 60269-4; DIN VDE 0636-40;DIN 49515/49360 |
|
AR |
240 to 700VAC |
5 to 900A |
IEC 60269-4; BS 88-4 |
|
aR/gR |
500 to 200VAC |
16 to 800A |
DIN 43620; DIN 43653 |
|
AR * |
700AC / 1300VAC |
50 to 1600A |
DIN 43653; DIN VDE 0636-40;IEC 60269-4;UL 248-13 |
|
* UL Recognition |
Class |
Size |
Type
|
Voltage rating
|
Current Rating
|
Standard
|
Product
Reference |
gRL |
00/1/2/3 |
Knife blade contact fuses
|
690VAC
|
16 to 800A
|
DIN 43620
|
URL |
Fuses with bolted contact
|
690VAC
|
16 to 800A
|
DIN43653
|
Cylindrical fuses
|
500 to 690VAC
|
6 to 100A
|
N/A
|
|
Class |
Size
|
Type |
Voltage rating
|
Product
Reference
|
gR/aR/gRL |
5 x 20 mm |
Cylindrical
fuse |
AC 250 V |
URZ |
6.35 x 32 mm |
AC 500 - 1000 V |
10 x 38 mm |
AC 600 - 1000 V |
14 x 51 mm |
AC 500/600V - 690/700 V |
22 x 58 mm |
AC 500/600 V - 690/700 V |
27 x 60 mm |
AC 660 V - 1000 V |
Standards: IEC 60269-4 and -1; DIN VDE 0636-23;UL 248-13 |
Fuses For Semiconductor Protection
North American and European Standard TYPE SQB Sizes 1, 2 AND 3 |
Long blade version |
Square body fuses type, SQB are
available in 3 different body sizes. Each size is available in various
mounting styles for global applications. Variety in body sizes, mounting
style and amp ratings allow the greatest flexibility in equipment
design. SQB fuses provide superior engineering for the protection
of today's power semiconductors. The silicated process together with
special shape and form of the pure silver melting elements give excellent
results of low I2t -values and high interrupting ratings.
And they are the most reliable under high cycling load conditions.
All fuses can be fitted with micro switches. |
- High interrupting rating 200 kA
- Very low I2t -values
- Voltage ratings AC 690/700 V and AC 1250/1300
V
- Suitable for North American and European standard
- Reliable also at high cyclic loading
- Fuse bases and Accessories are available
|
|
Class |
Size |
Voltage rating |
Current Rating |
Standard |
Product
Reference |
aR |
1/2/3 |
AC 700 V / AC 1300 V |
50 up to 1600 A |
DIN 43653 |
URS |
DIN VDE 0636-40 |
IEC 60269-4 |
UL 248-13 |
|
Download PDF Catalog for more Information |
Fuses For Semiconductor Protection European Standard Class gR |
Side and end view
|
This line of gRL class fuses offers superior
combination of two fuses into one. Type gRL fuses provide protection
to power electronic equipment and cables with low power losses and
low I2t-values simultaneously. Fuse type gRL offers:
Semiconductor protection against short circuit faults
via their Ultra Rapid "gR" characteristic.
Cable protection against overload via their "gG" characteristic. |
- High current limitation
- Low power losses
- Semiconductor protection against short circuit
faults
- Cable protection against overload current
- Low I2t -values
- High interrupting rating up to 200 kA
- Compliance with the following standards: IEC 60269-1
/ -2-1 and -4 DIN
- Class gRL follows the requirements of the new standardized
class gS
|
|
Download PDF Catalog for more Information |
Fuses For Semiconductor
Protection
Cylindrical Fuses - European Standard |
Isolated fuse base for fuses with
cylindrical contact caps shown below |
Cylindrical ultra-rapid fuses are
available in 6 different sizes. They can be fitted with or without
built-in striker pin for fuse blown indication or operation of micro-switches. |
- High interrupting rating up to 300 kA
- Voltage rating 250 up to 1000 V AC
- Protection of Power Semiconductors according
to IEC 60269-1 and -4
- With or without integrated striker pin
- Class aR according to IEC 60269-4 and DIN VDE 0636-40
- Class gR according DIN VDE 0636-40
- Fuse-Bases / Fuse-Clips and Accessories are available
|
|
Class |
Size |
Voltage rating |
Current Rating |
Standard |
Product
Reference |
gR
aR
gRL |
5 x 20 mm |
AC 250 V |
125 mA - 200 A |
IEC 60269-1
and -4
DIN
VDE 0636-23
UL 248-13 |
URZ |
6.35 x 32 mm |
AC 500 - 1000 V |
10 x 38 mm |
AC 600 - 1000 V |
14 x 51 mm |
AC 500/600V - 690/700 V |
22 x 58 mm |
AC 500/600 V - 690/700 V |
27 x 60 mm |
AC 660 V - 1000 V |
|
Download PDF Catalog for more Information |
DC-Application / Traction Fuse |
5000 VDC fuse |
DC-Fuses are offered in clip-mounted and bolt-design.
The fuses are used for applications in traction-, battery, and railway
main- circuits. They are largely used for the protection of frequency-inverters.
Because the application it is possible in a big variety you should
contact Hill Technical to have information regarding the use at different
voltage ratings, classes or L/R's. |
- Designed for heavy duty
applications
- Shock and vibration proved
- Some types with additional
microswitches
- Developed according customers
specification
- Individual tested time constants
- Designed for long lasting
live under severe service conditions
|
|
Class |
Voltage rating |
Current Rating |
Standard |
Product
Reference |
gR
aR |
DC 660 V - DC 5000 V |
6 A - 800 A |
UIC 550
IEC 60269-4
DIN
VDE 0636-23
|
URDC |
|
Download PDF Catalog for more Information |
Miniature Fuses G |
Fuse
holder for
5 x 20 mm fuse
|
- Very high interrupting
rating up to 70 kA
- High rated voltages up
to 10 kV
- High fuse ratings available
for semiconductor protection
- Fuse bases, clips and accessories
are available
|
|
Class |
Size |
Voltage rating |
Current Rating |
Standard |
Product
Reference |
F fast acting
T time lag
M medium time lag
FF very fast acting
|
Cylindrical fuses:
5 x 20
6.3 x 32
5 x 25
5 x 30
8 x 50
8 x 85
10 x 85
8 x 120
8 x 150 mm
Radial lead 2 pin fuses: KS, Ø 8.4
mm
SMD fuses: Voltage ratings:
65 V - 10 kV |
65 V - 10kV |
6 A - 800 A |
IEC 60127
DIN VDE 0820
CEE4
UL 248-14, UL 512
CSA-C22.2 No. 248.14
|
G |
|
Download PDF Catalog for more Information |
Medium Voltage Fuses For Capacitors |
|
Dual UNC thread drawing |
UNC
and bracket connected drawing |
Capacitor protection fuses can easily
be fitted direct onto capacitor bushings, because they are fitted with
threaded holes at both ends. Their electrical characteristic suits
the protection requirements of capacitors. Characteristic following
capacitor protection needs for back up protection. Cartridge type current
limiting Special mounting brackets available on request |
Voltage rating |
Current Rating |
Standard |
Product
Reference |
4.8 / 7.2 / 15.5 kV |
6.3 - 250 A |
IEC 60 282-1
IEC 60 549 |
HHC |
|
Download PDF Catalog for more Information |
High Voltage Fuses |
German DIN Standard For Air & Gas
Insulated Switchgears Outdoor Switchgears HV Fuse-links have parallel connected pure silver fuse-elements.
The design and method of production of the elements ensures narrow
tolerances of time-current characteristics. The fuse elements are wound
on a ceramic support and are attached to the silver plated connection
caps by means of spot-welding.
The connection caps are fitted inside the silver plated
copper end caps by spot welding. The copper end caps themselves are
press-fitted onto the porcelain tube, which is glazed inside and outside.
The end caps are furthermore mechanically fixed to the porcelain tube
and additionally sealed by a durable elastic sealing medium. This sealing
method has been proven over many decades of positive field experience
and ensures tightness against ingress of humidity.
|
Vertical cut |
Download PDF Catalog for more Information |
High Voltage Fuses |
Top view |
Motor Circuit Protection -
Din And British Standard
Motor Rated Fuses are available in German DIN Standard
and British Standard Design. The large variety in body sizes / mounting
style/ Voltage and Amp rating allow great flexibility for the designer
of switchboard panels. |
- Protection of Motor
circuits according IEC 60644High resistance against cyclic
and peak current loads / avoiding ageing because of high
motor start up currents
- Low power losses / minimizing
temperature increase in narrow contactor enclosures
- Low minimum interrupting
currents for operation of over-currents in the range 3 - 3.5
x rated current
- Availability of Temperature
limiters for switchgear protection against excessive temperature
rise
- Type tested according IEC 60470 in cooperation with the major European Panel
builders
- Available in DIN 43625 and
BS 2692 dimensions
|
|
Class |
Voltage rating |
Current Rating |
Standards |
Product
Reference |
Back up |
AC 3.6 - 7.2 kV |
50 - 315 A |
Dimensions:
DIN 43625 and BS 2692
Electrical:
IEC 60644
IEC 60470
IEC
60282-1 |
HHM |
|
Download PDF Catalog for more Information |
Medium Voltage Fuses |
Side view
|
European Standard For Installation Inside Transformers
Under Oil.
These are general-purpose fuses for installation
in transformers; they offer space and cost saving in distribution
transformer substation design. They are designed to protection against
short-circuit and internal transformer faults and also offer bursting
protection of the transformer through specific characteristic of
the fuse-link resistance against ageing |
|
Download PDF Catalog for more Information |
Medium Voltage Fuses - British
Standard |
|
Side view |
Medium voltage fuses according British Standard
are backup fuses for the protection of substations up to 24 kV. The
fuse links of this section comply with the following national and
international standards:
IEC 60282-1
BS 2692
ESI 12-8
Design and construction of these fuses follow the
well-proven concept of all high-voltage fuse-links. For pressure
resistant encapsulation, high-grade ceramic is used. Contact material
consists of silver plated high conductivity copper. The pure silver
melting elements are provided with appropriate notches to ensure
small time/current-curve tolerances and low let-through currents.
The arc quenching quartz sand is subject to special survey criteria
regarding its composition, grain size and humidity content.
|
Download PDF Catalog for more Information |
Medium Voltage Fuses - French
Standard |
|
Side view |
For Air & Gas
Insulated Switchgears Outdoor Switchgears
High-Voltage fuse-links of size 55 x 520 mm are
suitable for the protection of power transformers used in energy
distribution. Usually they are used for
indoor application, outdoor use is possible. In case
of a short circuit the fuse will interrupt fault currents between five
times the fuse rated current and the
rated breaking current. Standards: IEC 60282-1 NFC 64210 |
Download PDF Catalog for more Information |
Medium Voltage Fuses -
European Standard |
|
|
Medium voltage fuses Plug-in fuses
for overhead lines
Medium voltage fuse links including overhead line
connectors are provided as a set. They allow in overhead lines to
provide fuse protection on pole mounted distribution transformers.
The set consists of a high voltage fuse link including a set of contacting
armatures
|
Download PDF Catalog for more Information |
Low Voltage Fuses - European
NH Knife-Blade Fuse System |
Side and end view |
Description: European NH Knife-Blade Fuse System
SIBA NH Fuse-links with top and center indicator
are available in a large variety of voltage ratings, body sizes and
operating classes:
Sizes: 000, 00, 0, 1, 2, 3 and 4
Voltage ratings: AC 400 / 500 / 690 / 1000 / 1500
V
Fuse bases and accessories available, made of sheet
steel base plate with ceramic support Low power losses and temperatures
All fuse links are entirely corrosion
resistant |
Operation class
|
Application
|
gG
|
General Purpose Cable and Line protection
|
gB
|
For general application
|
aM
|
Motor circuit short circuit protection
|
gTr
|
General Purpose Transformer Protection
|
gTF
|
For general application
|
|
Standards: IEC 60269-1-2 / EN 60269-1-2
DIN VDE 0636 part 201
DIN VDE 0636 part 2011
DIN 43620
Approvals: Germany, Austria, Switzerland
Combination indicator (top and center) for easy
identification of blown fuses
High interrupting rating up to 120 kA
Voltage ratings AC 400 - 1500 V
Operation classes gG / gB / aM / gTr / gTF available
for all applications
Removal tags: Standard design in metal, insulated removal
tags available for increased safety
|
Download PDF Catalog for more Information |
Fuses For Semiconductor Protection - European Standard |
|
Top, end and side view |
They are designed to protect Power Semiconductors
according to IEC 60269-1 IEC 60269-4 and comply with DIN 43653. Fuses
are available with or without top indicator and trip microswitch. aR class 10 A - 400 A according to IEC 60269-4 and
DIN VDE 0636-40. Fuse Bases and Accessories are also available Sizes 000 And 00 Class: aR Voltage rating: AC 660 V - AC 1000 V Current rating: 10 A to 400 A Standards: DIN 43653, IEC 60269-1 IEC 60269-4, DIN
VDE 0636-40 and UL 248-13 These fuses have extremely high interrupting
rating 100 kA - 300 kA with voltage ratings AC 660 V - AC 1000 V |
Download PDF Catalog for more Information |
Fuses For Semiconductor Protection - European Standard |
|
Type DV
|
TYPE D0 / D D-Fuses, also known as type Diazed/
Neozed fuses are supplied in eight different sizes, ND, DII, DIII,
DVI, DV, D01, D02, D03. All fuses have color-coded blown fuse indicators. Voltage rating: AC 440 V - AC 500 V Current rating: 2 A to 200 A Class: gR / aR Standards: IEC 60269-4, DIN VDE 0636-40 DIN 49515
/ 49360 Class gR for rated currents up
to 100 A
Class aR for rated currents above 100 A All fuses have blown fuse indicators Protection of Power Semiconductors according to IEC
60269-4 Fuse Bases and Accessories are available |
Download PDF Catalog for more Information |
Knife Blade Contact - German Standard |
|
Side and end view |
|
Ultra-rapid knife blade contact fuses type NH are
available in many different sizes and four voltage ratings. They
follow DIN/VDE -IEC standard and can be fitted in open fuse bases.
Usage in fuse bases or switches requires the comparison of the power
loss of the fuse with the power acceptance of the base or switch.
All type NH-fuses are available with either integral
blown fuse indicator or a separately fitted trip indicator fuse for
microswitch operation. Class: aR/gR
Sizes: 000 / 00 / 0 / 1 / 2 and 3
Voltage ratings: AC 500 V - 2000 V
Current ratings: 16 A up to 800 A
High interrupting rating up to 120 kA
Voltage rating AC 500 V - AC 2000 V
Compliance with DIN 43620 and DIN 43653 standard
Fuses with blown fuse combination indicator
Class aR according to IEC 60269-4 and DIN VDE 0636-40
and
Class gR according to DIN VDE 0636-40
Fuse bases / Switches and Accessories are available
|
Download PDF Catalog for more Information |
Fuses For Semiconductor Protection - European-British Standard |
|
Size 8.4 x 38 m |
Protection of Power Semiconductors
according to IEC 60269-4
Complies with BS 88 Standard and are available with or without striker for microswitch
operation, Class aR 5 A - 900 A according to IEC 60269-4 Standards: IEC 60 269-4, BS 88-4 Class: aR Voltage ratings: AC 240 V - AC 700 V Current ratings: 5 A - 900 A High interrupting rating 100 kA Voltage rating AC 240 V - AC 700 V |
Download PDF Catalog for more Information |
D Fuses |
|
Type D II |
The diameter of the bottom
of the fuse-links are garduating, corresponding to the fixed diameter
of the gauge piece, this prevents them from being interchangeable.
Voltage rating: AC 400 V - AC 500 V / DC 250 V - DC 500 V
Current rating: 0.5 A to 200 A Class: gG/gL Standards: IEC 60 269-3-1, DIN VDE 0636 Part 301, DIN 49515 / 49360 / 49365 / 49522 Systems: ND - AC 500 V - DIN 49360 D - AC 500 V - DIN 49515 / DO - AC 400 V - DIN 49522 |
Download PDF Catalog for more Information |
Class |
Voltage rating |
Current Rating |
Standards |
Product Reference |
AR |
660 to 1000VAC |
10 to 400A |
DIN 43653; IEC 60269-4; DIN VDE 0636-40; UL 248-13 |
URB |
gR/aR |
440 to 500VAC |
2 to 200A |
DIN VDE 0636-40; DIN 49515 / 49360 |
URD |
gR/aR |
660 to 5000VDC |
6 to 800A |
IEC 60269-4;DIN VDE 0636-40;DIN 49515/49360 |
URDC |
AR |
240 to 700VAC |
5 to 900A |
IEC 60269-4; BS 88-4 |
URE |
aR/gR |
500 to 200VAC |
16 to 800A |
DIN 43620; DIN 43653 |
URM |
AR * |
700AC / 1300VAC |
50 to 1600A |
DIN 43653; DIN VDE 0636-40;IEC 60269-4;UL 248-13 |
URS |
* UL Recognition
Class gRL,
Size: 00 / 1 / 2 / 3
Product Reference: URL
Type |
Voltage rating |
Current Rating |
Standard |
Knife blade contact fuses |
690VAC |
16 to 800A |
DIN 43620 |
Fuses with bolted contact |
690VAC |
16 to 800A |
DIN43653 |
Cylindrical fuses |
500 to 690VAC |
6 to 100A |
N/A |
Class gR/aR/gRL
Size: Cylindrical fuse
Product Reference: URZ
Size |
Voltage rating |
5 x 20 mm |
AC 250 V |
6.35 x 32 mm |
AC 500 - 1000 V |
10 x 38 mm |
AC 600 - 1000 V |
14 x 51 mm |
AC 500/600V - 690/700 V |
22 x 58 mm |
AC 500/600 V - 690/700 V |
27 x 60 mm |
AC 660 V - 1000 V |
Standards: |
IEC 60269-4 and -1; DIN VDE 0636-23;UL 248-13 |
|
|
|